I3 power switch and end stops assembly

From RepRap
Revision as of 04:27, 14 August 2015 by Qing (talk | contribs)
Jump to: navigation, search


Assembly instructions

  1. Bill of materials
  2. The main panel frame assembly
  3. Y-axis assembly
  4. X-axis assembly
  5. Z-axis assembly
  6. Connecting X-axiz and Z-axiz
  7. Power and LCD assembly
  8. Extruder assembly
  9. Heated bed assembly
  10. power switch and end stops assembly
  11. Control Board assembly and wiring
  12. Circuit Diagram

Y Axis

Need parts:

  • 1×endstop switch
  • 1×endstop switch plastic parts
  • 2×M3*16 screw
  • 1×M3*20 screw
  • 3×M3 lock nut
  • 4×M3 flat gasket

Repair Parts

Step 1

Repair the endstop switch with 3.2mm drill.

Prusa i3 power supply assembly.jpg

Step 2

Welding endstop switch and the power switch.

Power switch and endstop switch assembly1.jpg

Step 3

Insert heat shrink tube and weld.

Power switch and endstop switch assembly2.jpg

Step 4

Heat up the heat shrink tube

Power switch and endstop switch assembly3.jpg

Power supply switch assembly

Step 1

First put the power supply cable into the acrylic sheet bottom and take out from Y axis acrylic square hole, and then weld.

Power switch and endstop switch assembly4.jpg

Step 2

Power supply plug weld “o” end, Twisted Pair cable weld “-” end, positive is on one side, negetive Is on other side.

Power switch and endstop switch assembly5.jpg

Step 3

Insert Twisted Pair cable and connect power supply.

Power switch and endstop switch assembly6.jpg
Power switch and endstop switch assembly7.jpg

Endstop switch assembly

Y-axis endstop switch

Need parts:

  • 1×Y-axis endstop switch
  • 1×Plastic parts
  • 2×M3*16 screw
  • 1×M3*20scew
  • 3×M3 lock nut
  • 4×M3 flat gasket

Power switch and endstop switch assembly8.jpg

Step 1

Insert 2 pcs M3*16 scew and tighten.

Power switch and endstop switch assembly9.jpg

Step 2

The end of Y axis back motor M8 rod insert M3*20 scew and then tighten.

Power switch and endstop switch assembly10.jpg

X-axis endstop switch

Step 1

If them can not close together, please repair with knife.

Power switch and endstop switch assembly12.jpg
Power switch and endstop switch assembly13.jpg

Step 2

M3*20scew tighten.

Power switch and endstop switch assembly14.jpg

Z-axis endstop switch

Step 1

Limit shrapnel can be removed.

Power switch and endstop switch assembly15.jpg